HID to LED Wattage Conversion Chart (2026): Complete Replacement Guide for High Bays, Parking Lots & Flood Lights

If you’re still lighting a warehouse, parking lot, or stadium with metal halide (MH) or high-pressure sodium (HPS) fixtures, you’re probably paying 40–70% more on energy than you need to — plus a maintenance bill for lamps that burn out every year or two. Switching to LED solves both problems, but only if you pick the right replacement wattage.

The single most common mistake buyers make is ordering a “one-to-one” swap — replacing a 400W HID fixture with a 400W LED fixture. That’s a 60% waste of money and light. This guide gives you the exact conversion chart, explains why the numbers aren’t 1:1, and walks through a real cost example so you can budget your retrofit with confidence.

Why You Can’t Convert HID Watts to LED Watts 1:1

Watts measure energy consumed, not light delivered. What you actually need to match is lumens — the amount of visible light a fixture produces. Three factors make HID dramatically less efficient than LED:

  1. Lumen depreciation (LLD). A new 400W metal halide lamp may produce ~36,000 lumens on day one, but within a year it often drops below 20,000. Yet you keep paying for 400 watts of electricity the whole time.
  2. Ballast losses. HID fixtures use a magnetic ballast that consumes extra power. A “400W” metal halide system actually draws ~455 watts at the wall.
  3. Poor color rendering. High-pressure sodium runs around 22 CRI (colors look gray and washed out), and metal halide sits near 65–70. Quality LED fixtures deliver 70–80+ CRI, so the light feels brighter at the same lumen count.

A modern LED high bay produces 130–160 lumens per watt versus roughly 60–80 effective lumens per watt for an aged HID system. That’s why a 150W LED replaces a 400W metal halide in most real-world applications.

The Quick Conversion Chart: HID → LED

Use this table as your starting point. The LED wattage shown targets ~140–150 lm/W fixtures (the current standard for DLC-listed commercial products).

HID Wattage (Metal Halide)Approx. Initial LumensRecommended LED WattageLED Output (Typical)
70W~5,600 lm20–25W3,000–3,750 lm
100W~8,000 lm30–40W4,500–6,000 lm
150W~12,000 lm50–60W7,500–9,000 lm
175W~14,000 lm60–80W9,000–12,000 lm
250W~20,000 lm80–100W12,000–15,000 lm
320W~26,000 lm100–120W15,000–18,000 lm
400W~36,000 lm120–150W18,000–22,500 lm
450W~40,000 lm150–180W22,500–27,000 lm
1000W~90,000 lm300–400W45,000–60,000 lm
Rule of thumb: for metal halide, LED watts ≈ HID watts × 0.35–0.40. For high-pressure sodium (which starts brighter but has terrible CRI), you can go slightly lower — a 400W HPS is typically replaced by a 120–150W LED.

Conversions by Fixture Type

UFO High Bay Lights (warehouses, gyms, workshops)

Old FixtureLED ReplacementMounting Height
250W MH high bay80–100W UFO12–15 ft
400W MH high bay150W UFO15–20 ft
400–600W MH high bay200–240W UFO20–30 ft
1000W MH high bay300–400W UFO30–40 ft

Shoebox / Parking Lot Lights

Old FixtureLED ReplacementTypical Pole Height
250W MH60–100W shoebox15–20 ft
400W MH / HPS100–150W shoebox20–25 ft
1000W MH / HPS300W shoebox30–40 ft

Tip: if your poles are 30 ft or taller, choose the higher end of the range — light spread matters as much as raw lumens at that height. Look for fixtures with Type III or Type V optics depending on your lot layout.

LED Flood Lights (stadiums, facades, signage)

Old FixtureLED Replacement
250W MH flood80–100W LED flood
400W MH flood120–150W LED flood
1000W+ stadium lights300–600W LED flood

LED Corn Bulbs (retrofit into existing housings)

Old LampLED Corn Bulb
100W MH27–36W corn bulb
175W MH54–60W corn bulb
250W MH80W corn bulb
400W MH / HPS100–120W corn bulb
Corn bulb warning: bypassing the HID ballast is mandatory — an LED corn bulb on a magnetic ballast will flicker and fail early. Also check enclosed-fixture ratings: most corn bulbs need open or ventilated housings to manage heat.

Wall Packs & Canopy Lights

Old FixtureLED Replacement
100–150W MH wall pack26–40W LED wall pack
250W MH wall pack60–80W LED wall pack
175W MH canopy40–60W LED canopy light

How Bright Do You Actually Need? (Footcandle Targets)

Before you order, match your space to the Illuminating Engineering Society (IES) recommended light levels. This prevents over-buying — and over-paying:

ApplicationRecommended Light Level
Open parking areas0.5–2 fc
Parking entrances & drive lanes2–5 fc
Warehouse storage (bulk)5–10 fc
Warehouse aisles with picking10–20 fc
Shipping & receiving docks10–15 fc
General manufacturing20–50 fc (task dependent)
Gyms & recreation courts20–30 fc
Outdoor sports fields (amateur)15–50 fc (sport dependent)

Real Cost Example: Retrofitting a 100-Fixture Warehouse

Let’s run the numbers for the most common retrofit — replacing 400W metal halide high bays with 150W LED UFOs:

  • Old draw per fixture: 400W lamp + ballast = 455W
  • New draw per fixture: 150W LED = 150W
  • Savings per fixture: 305W
  • Operating hours: 12 hrs/night × 365 days = 4,380 hrs/year
  • Electricity rate: $0.13/kWh (US commercial average)

Energy savings per fixture: 0.305 kW × 4,380 hrs × $0.13 ≈ $174 per year

For 100 fixtures: ≈ $17,400 per year — before counting maintenance.

Add the maintenance side: a metal halide lamp typically needs replacement every 12–18 months. At roughly $40–60 per lamp plus lift rental and labor (often $100+ per visit), a 100-fixture facility easily spends another $4,000–8,000 per year keeping HID alive. A quality LED high bay rated at 50,000+ hours runs 11+ years at the same schedule — essentially maintenance-free for a decade.

5 Mistakes to Avoid When Converting HID to LED

  1. Shopping by wattage instead of lumens. Two 150W fixtures can differ by 30% in output. Compare the lumen box, not the wattage label.
  2. Ignoring DLC certification. If a fixture isn’t DLC-listed, most US utility rebate programs won’t pay you anything. DLC-listed products can return 20–50% of project cost in rebates.
  3. Skipping dimming and controls. Occupancy sensors and daylight harvesting in a warehouse can cut LED energy use another 20–50%. Retrofit without controls and you leave money on the table.
  4. Choosing the wrong color temperature. For outdoor commercial and industrial spaces, 5000K is the North American standard. Warmer 3000–4000K suits indoor retail and hospitality.
  5. Keeping the old ballast. Any LED retrofit (corn bulbs especially) requires bypassing or removing the HID ballast. Running LED through a ballast causes flicker, premature failure, and voided warranties.

FAQ: HID to LED Conversion

Can I put LED corn bulbs in my existing HID fixtures?

Yes, if the fixture is in good condition, the ballast is bypassed, and the housing allows adequate heat dissipation. Corn bulbs are the cheapest retrofit path; full LED fixtures deliver better optics and longer life.

What voltage do commercial LED fixtures run on?

Most DLC/UL-listed commercial LED fixtures accept 100–277V AC. For 480V systems (common in large US industrial sites), you’ll need a step-down transformer or a 347–480V driver option.

Are utility rebates still available in 2026?

Yes — most US utility programs still offer prescriptive rebates for DLC-listed LED fixtures and controls, though amounts vary by state and program budget. Check your utility’s business rebate portal before ordering.

How long do LED high bays actually last?

Quality fixtures are rated L70 at 50,000–80,000 hours — meaning they still emit 70% of initial brightness at that age. At 12 hours per night, that’s 11–18 years of service.

Planning a retrofit? The team at Mastled Lighting manufactures DLC/UL-certified UFO high bays, shoebox lights, and flood lights with US warehouse stock — request a free photometric layout and quote for your project to see exact fixture counts and payback period before you commit.